The Merlin CT1250 Acts As An Interlock Between The Ventilation System And The Gas Solenoid Valve. The System Has A Built In Power Monitor Which Is A Method Used For Interlocking A Kitchens Gas Supply:
Allows Compliance with BS6173: 2001 for commercial kitchens
Clear LED display for system indications
Complete all in one box
Can be used when pressure differential switches cannot be used e.g. wall-mounted fans
Reliable method of interlock, with no moving parts there's little to go wrong
Straightforward to install and calibrate
The CT1250 can be easily adjusted to the users requirements
This method is not recommended with belt driven fans
Easy installation
BMS Terminals Normally Closed or Normally open and common
Will accept remote emergency shut-off buttons
Three year warranty
All Merlin systems are designed to comply with the latest CE requirements and low voltage directives
The Merlin CT1250 ventilation interlock system, with built in current monitoring, is designed specifically for use in commercial kitchens to meet BS6173: 2001, which is now a much-recognised standard in the catering industry. This panel is to be used when the kitchen appliances do have flame failure devices, therefore Gas proving is not a requirement. The Merlin CT1250 acts as an interlock between the ventilation system and the gas solenoid valve. The system has a built in power monitor which is a method used for interlocking a kitchens gas supply with the ventilation system. As an alternative to pressure differential switches the CT1250 is designed to monitor the electrical current going to a ventilation fan. When the fan is turned "on" the CT1250 monitors the electrical current going to the fan motor, when there is sufficient current going to the fan motor our panel receives a signal to indicate the fans are operating. Turning the key to the "on" position will open the gas solenoid valve. If the fans should fail, the "fan fault" LED on the panel will illuminate and the gas solenoid valve will close. When there is a "fan fault" the supply fan or extract fan led on the Merlin CT1250 panel fascia will flash. This informs the electrician or kitchen staff which fan has failed. Operating the system in the above manner will ensure the requirements of BS6173: 2001 are fully met where all the catering equipment has flame failure devices fitted. Installation for the Merlin CT1250 is easy as there is no calibration. Wiring of the system is straightforward using volt free connections for all BMS and remote emergency stops. A corgi-registered installer would be required to fit the gas solenoid valve.